Incognito Fire & Security
Engineering search
Search by panel model, fault message, manufacturer or engineering question.
120 relevant results for “Apollo Fire Detectors manuals”
Interpreted as: apollo fire detector detector sensor detector detector sensor detector sensor manual
Product (16)
Apollo Fire Detectors AlarmSense
Apollo Fire DetectorsDetection Device. Two wire fire detection and alarm device range listed in Apollo Fire Detectors current product catalogue. Source reviewed record.
Apollo Fire Detectors Orbis
Apollo Fire DetectorsDetection Device. Conventional fire detection product range listed in Apollo Fire Detectors current product catalogue. Source reviewed record.
Apollo Fire Detectors Series 65
Apollo Fire DetectorsDetection Device. Conventional fire detection device range listed in Apollo Fire Detectors current product catalogue. Source reviewed record.
Apollo Fire Detectors XP95
Apollo Fire DetectorsDetection Device. Analogue addressable fire detection product range listed in Apollo Fire Detectors current product catalogue. Source reviewed record.
Apollo Fire Detectors XPander
Apollo Fire DetectorsDetection Device. Wireless fire detection product range listed in Apollo Fire Detectors current product catalogue. Source reviewed record.
Apollo Fire Detectors Discovery
Apollo Fire DetectorsDetection Device. Analogue addressable detection range presented by Apollo for applications requiring configurable detector behaviour. Source reviewed record.
Apollo Fire Detectors Soteria
Apollo Fire DetectorsDetection Device. Addressable fire detection range using Apollo CoreProtocol and listed in the manufacturer current product catalogue. Source reviewed record.
C-TEC CA414 CAST Programmable Multi-Sensor
ApproximateC-TECDetection Device. Programmable CAST smoke-and-heat multi-sensor with five documented operating modes and onboard isolator. Source reviewed record.
C-TEC CA402 CAST Programmable Heat Detector
C-TECDetection Device. Programmable CAST heat detector with onboard short-circuit isolator for XFP and ZFP CAST panels. Source reviewed record.
C-TEC CA408 CAST Detector Base
C-TECAccessory. Detector base for compatible CAST and CAST-PRO detectors, with remote-indicator terminals, locking mechanism and identification tag. Source reviewed record.
C-TEC CA416 CAST Optical Smoke Detector
C-TECDetection Device. CAST optical smoke detector with onboard short-circuit isolator for XFP and ZFP CAST panels. Source reviewed record.
C-TEC CP402 CAST-PRO Heat Detector
C-TECDetection Device. CAST-PRO heat detector with documented A1R and A2 modes and onboard short-circuit isolator. Source reviewed record.
C-TEC CP411 CAST-PRO CO Smoke and Heat Multi-Sensor
C-TECDetection Device. CAST-PRO carbon-monoxide, smoke and heat multi-sensor with onboard short-circuit isolator. Source reviewed record.
C-TEC CP414 CAST-PRO Smoke and Heat Multi-Sensor
C-TECDetection Device. CAST-PRO smoke-and-heat multi-sensor with eight documented operating modes and onboard isolator. Source reviewed record.
C-TEC CP416 CAST-PRO Smoke Detector
C-TECDetection Device. CAST-PRO smoke detector with two documented sensitivity modes and onboard short-circuit isolator. Source reviewed record.
C-TEC CPDUCT/OPT CAST-PRO Duct Detector
C-TECDetection Device. CAST-PRO duct detector supplied with CP416 smoke detector and CA408 base for XFP and ZFP CAST systems. Source reviewed record.
Guide (3)
Apollo Detector Fault Database
Apollo Detector Fault Database: fire alarm software workflow for engineers covering evidence, reports and service history.
Fire Alarm Detector Spacing Calculator
Fire Alarm Detector Spacing Calculator: fire alarm software workflow for engineers covering evidence, reports and service history.
How Fire Alarm Detectors Work: Smoke, Heat, Multi-Sensor and Beam Detectors Explained
Learn how smoke, heat, multi-sensor, beam and aspirating fire detectors work, where they should be used and their advantages and limitations.
Blog (88)
Apollo Discovery detector contamination: how to report it
Apollo Discovery detector contamination: how to report it: practical fire alarm engineering guidance covering fault evidence, site history and reports.
Detector Guards and Physical Protection of Fire Alarm Devices
When fire alarm detectors and devices need physical protection such as guards or cages, the trade-offs involved, and what to check — for UK fire alarm engineers.
Airflow and Fire Detector Performance
How airflow and ventilation affect fire detector performance, why high air-change rooms matter, and what to check — for UK fire alarm engineers.
Disposal of Fire Detectors and Ionisation Sources
How fire detectors are disposed of responsibly, why ionisation devices need special handling, and what to check — for UK fire alarm engineers.
Fire alarm beam detector fault: alignment and environment
Fire alarm beam detector fault: alignment and environment: practical fire alarm engineering guidance covering fault evidence, site history and reports.
Fire alarm cooking fumes false alarm: detector suitability
Fire alarm cooking fumes false alarm: detector suitability: practical fire alarm engineering guidance covering fault evidence, site history and reports.
Fire Alarm Detector Compatibility: Mixing Devices and Manufacturers
Why fire alarm devices and panels must be compatible, the risks of mixing manufacturers, and how to check before replacing a device — for UK engineers.
Fire alarm detector contamination: report wording that works
Fire alarm detector contamination: report wording that works: practical fire alarm fault-finding guidance for engineers, with evidence, reporting and…
Fire alarm water leak above detector: report evidence
Fire alarm water leak above detector: report evidence: practical fire alarm engineering guidance covering fault evidence, site history and reports.
Fire Detector Functional Testing: Methods and Test Equipment
How fire detectors are functionally tested — smoke and heat test equipment, why it proves the whole signal path, and good practice — for UK engineers.
Fire Detector Types Explained: Smoke, Heat, Multi-Sensor and Where Each Belongs
A UK engineer's guide to fire detector types — optical smoke, ionisation, heat and multi-sensor — how each responds to fire and where each belongs.
Multi-Sensor Fire Detectors Explained
What multi-sensor fire detectors are, how they help balance sensitivity and false alarms, and what to check — for UK fire alarm engineers.
Analogue Detector Sensitivity and Drift Compensation
How analogue addressable detectors report a value, how drift compensation and sensitivity work, and what to check — for UK fire alarm engineers.
Aspirating smoke detector fault: filter and airflow notes
Aspirating smoke detector fault: filter and airflow notes: practical fire alarm engineering guidance covering fault evidence, site history and reports.
Beam Smoke Detectors Explained: How Optical Beam Detection Works
How optical beam smoke detectors work, where they suit — warehouses, atria and high spaces — their alignment and maintenance needs, for UK fire alarm engineers.
Detector Contamination and Cleaning: Keeping False Alarms Down
Why fire detectors get contaminated, how it causes false alarms, and the right way to clean or replace them — a practical guide for UK engineers.
Detector End-of-Life and Replacement
Why fire detectors have a working life, how end-of-life and replacement are managed, and what to check — for UK fire alarm engineers.
Detector Siting and Spacing: The Principles Behind BS 5839-1 Coverage
The principles behind fire detector siting and spacing — coverage, ceiling effects and obstructions — and why the exact figures come from BS 5839-1.
Flame Detectors: UV, IR and Where They Belong
How UV and IR flame detectors work, where they suit fast-flaming fire risks, their false-alarm sources, and what to check — for UK fire alarm engineers.
Heat Detector Classes and Selection
How heat detectors are classified, why matching the class to the environment matters, and what to check — for UK fire alarm engineers.
FAQ (1)
Glossary (6)
Flame detector
A detector responding to the optical signature of flame (IR and/or UV), used for fast-developing fuel fires where smoke detection is too slow.
Multi-sensor detector
A detector combining sensing principles (typically optical and heat) to improve discrimination between real fire signatures and nuisance sources.
Optical smoke detector
A point detector sensing light scattered by smoke particles in its chamber; effective on smouldering fires, more prone to dust and steam nuisance alarms.
Beam detector
An optical detector projecting a beam across a large space, signalling when smoke obscures it; alignment and building movement are its main maintenance issues.
Heat detector
A detector operating on fixed temperature, rate of temperature rise, or both; used where smoke detection would false-alarm, at the cost of slower response.
PIR detector
A passive infrared movement detector; siting, mounting height and environment (heat sources, pets, draughts) determine its reliability.
Manufacturer (1)
Official resource (3)
Apollo Fire Detectors official YouTube channel
Apollo Fire DetectorsOfficial videos from Apollo Fire Detectors. Use this official Apollo Fire Detectors resource as a primary route to videos information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.
Product ranges and downloads
Apollo Fire DetectorsManuals and documentation from Apollo Fire Detectors. Use this official Apollo Fire Detectors resource as a primary route to manuals information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.
Apollo official installation, maintenance and testing videos
Apollo Fire DetectorsOfficial videos from Apollo Fire Detectors. Use this official Apollo Fire Detectors resource as a primary route to videos information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.
Forum (2)
beam detector blocked by new racking: what would you record first?
Admin starter thread for engineers. Scenario: beam detector blocked by new racking. Prompt: what would you record first? Use this structure if helpful: - Panel make/model and exact event text. - Zone, loop, address, device label and phy
water leak above detector: what would you record first?
Admin starter thread for engineers. Scenario: water leak above detector. Prompt: what would you record first? Use this structure if helpful: - Panel make/model and exact event text. - Zone, loop, address, device label and physical locat