Nittan Europe

Official sources checked

Fire detection devices and systems represented from Nittan Europe's official product information.

Reviewed products
7
Panel records
2
Verified faults
20
Reviewed parts
0

Official resource links last checked July 19, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Fire detection devices, addressable systems, manufacturer product information
Known names
Nittan Europe, Nittan

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Lifecycle not classified

EvolutionNo lifecycle claim made
SensortecNo lifecycle claim made

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Io ModuleSource-checked

EV-2I1O Dual Input / Single Output Module

Loop-powered Evolution addressable module with two Class B inputs, one mains-rated relay and an integral negative-line isolator.

Detection DeviceSource-checked

EV-DP Dual Optical Smoke Detector

Evolution analogue addressable dual-optical smoke detector using infrared and blue-light sensing to discriminate steam and dust.

Call PointSource-checked

EV-MCP2-SCI-IP24 Indoor Manual Call Point

Indoor Evolution addressable resettable manual call point with an integral negative-line short-circuit isolator.

Detection DeviceSource-checked

EV-PY-SCI Optical Smoke Detector with Isolator

Evolution analogue addressable optical smoke detector with an integral bi-directional negative-line short-circuit isolator.

Repeater PanelSource-checked

EVO-5020 Remote Control Terminal

Ad-NeT peer-to-peer remote control terminal for evo+5000 systems, providing network display and control through the same user interface.

Control PanelSource-checked

EVO-5400

One-to-four-loop evo+5000 addressable control panel with Ad-NeT networking and PC-NeT programming software.

Control PanelSource-checked

Evolution 1

Single-loop addressable control panel with a 4.3-inch touchscreen and documented firmware-generation networking boundary.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 1 shown
Official websiteOfficialLink checked

Fire detection products

Published by Nittan Europe

Incognito summary

Use this official Nittan Europe resource as a primary route to website information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
starting with the manufacturer's current product and service information
Intended audience
engineers, specifiers, maintainers and system owners
Product range covered
Nittan Europe product and support resources
Checked Oct 2, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
Nittan Evolution • Battery high impedance faultBattery internal resistance too highThe panel has measured the battery internal resistance and determined it is too high. The batteries will need to be replaced.Nittan Evolution • Battery RemovedStandby batteries missing or disconnectedCheck the battery fuse, check that battery connections are secure, check battery voltage (should be around 26-27V for well-charged batteries), check that the two batteries are connected in series, and check the charger fuse.Nittan Evolution • Break in -ve wire (ISOLATOR FAULT)Nittan evolution 1: Break in -ve wire (ISOLATOR FAULT)Reported as an ISOLATOR FAULT with a description. The manual says to use the same method to locate the break (re-run the loop search and check the detailed loop report). In its example, the break is between address 150, seen from side A only, and address 152, seen from side B only; this applies if the loop is addressed sequentially.Nittan Evolution • Break in +ve wire (ISOLATOR FAULT)Nittan evolution 1: Break in +ve wire (ISOLATOR FAULT)The manual says the panel's loop isolator monitors the addressable loop for open and short circuit faults, reported as ISOLATOR FAULTS with a description. For a break in the positive wire, it says to locate the cable break by re-running the loop search and checking the detailed loop report after the search is complete.Nittan Evolution • Cable break (loop contents different from expected)Nittan evolution 1: Cable break (loop contents different from expected)If the loop contents differ from what was expected, the manual lists a cable break as a probable cause. If a system is only wired as a loop, any breaks will be reported and can be located as in section 12.1. If a system uses spurs, a cable break in a spur will not be seen: look for missing device addresses in the loop report.Nittan Evolution • Charger FaultPower supply is not charging the batteriesThe panel has determined that the power supply is not charging the batteries. This is likely to be a problem with the Charger PCB — contact the supplier to arrange a replacement.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 184 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.