24A Output
Not yet verifiedShorted 24A Output
48 fault records for this panel, each labelled with its review status and, where one is cited, the source document it comes from. FireClass FC501 addressable fire control panel. This record covers product identity and official documentation only; no fault-code content has completed technical review.
48 records
Shorted 24A Output
Shorted 24R Output
The control panel's batteries charger is not working correctly
The fire panel resets to default data
Smoke detector only; the dirty threshold has been exceeded
Communication fault on display controller
Leakage to earth
Both the CSG paths are down
The fire signal is not acknowledged from the central station. This fault is latched, per the source.
Checksum fault
The CSG is installed but it is not communicating with the panel
Communication lost with IP controller
Communication lost with IP receiver
LOG fault
Communication loop fault controller
Left side loop short
Local short on loop controller
Loop negative signal open
Right side loop short
Loop positive signal open
The devices on the loop x (= 1, 2 or 3) do not communicate properly with the panel; check the quality of wiring. This is a parameterised message covering any of the three loops, as printed in the source.
The control panel batteries are empty
The control panel is not powered from the mains
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source states.
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4; y from 1 to 5); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source states.
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source states.
Loop device does not answer
Loop device without address
Open circuit on input module
Main fault
The CSG primary path is down
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source states.
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source states.
Data programming checksum fault
Aux Controller data programming checksum fault
A PSTN action not acknowledged
The communication with PSTN controller is lost
A repeater on the RS485 does not respond
Several loop devices have the same address
SC x (= 1 or 2) open terminal. This is a parameterised message covering either SC1 or SC2, as printed in the source.
SC x (= 1 or 2) short circuit. This is a parameterised message covering either SC1 or SC2, as printed in the source.
The CSG secondary path is down
Short circuit on input module
An output module relay is not switched
Telephone line fault
Detector head is not fitted correctly or missing from the base
Different loop device from that programmed in the panel
A loop device has an incorrect value