AUX. SUPPLY FAULT
Not yet verifiedAUX. SUPPLY FAULT LED
This indicates the auxiliary supply has a fault.
9 fault records for this panel, each labelled with its review status and, where one is cited, the source document it comes from. Global Fire Equipment's Orion 2, 4 and 8 zone conventional fire alarm control panel.
9 records
AUX. SUPPLY FAULT LED
This indicates the auxiliary supply has a fault.
BATTERY FAULT LED
This indicates there is a low voltage level on the batteries, or the battery charger circuit has failed.
EARTH FAULT LED
When this indicator is on, there is leakage current flowing between the earth connection/wiring and any other wire connected to the panel.
General FAULT LED
This LED indicates any fault condition present on the panel. If there is a communication fault between the ORION and an ORION MINI-REP, a Sounder/Relay module or a GFE-ADLI V2 module, this LED flashes once per second. If there is a site memory corruption, it flashes once every 0.5 seconds.
RM FAULT (relay module output circuit)
If there is an RM output circuit fault, the general FAULT LED is lit and the DISABLE SELECTED ZONES LED in the Disablements section flashes.
SOUNDER FAULT (conventional sounder circuit)
If there is a conventional sounder output circuit fault, the general FAULT LED is lit and the DISABLE SOUNDERS LED in the Disablements section flashes.
SUPPLY FAULT LED
This LED is on whenever the main supply has been removed or has dropped below 20 volts.
SYSTEM FAULT LED
This LED is lit whenever there is a processor failure or corruption of the panel firmware.
Zone or monitored input fault indication
Individual zone and monitored input indicators are provided for both fire/alarm and fault conditions. A flashing zone/input Fault LED together with the general FAULT LED indicates a fault in that zone. The same zone/input Fault LED is also used, steady and alongside the Disabled status LED, to show that zone or input is disabled.
One question, answered from the fault records above. If they don't cover it, we'll say so. Sign up free for 5 questions a day across every panel.
Records marked “sourced — not yet independently verified” carry a real citation but have not yet completed formal review. Always confirm against the manufacturer's current documentation before acting on site.
Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.