5/8V
Not yet verifiedPremier AL power supply indicator: 5/8V
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: 5 V supply low.
18 fault records for this panel, each labelled with its review status and, where one is cited, the source document it comes from.
18 records
Premier AL power supply indicator: 5/8V
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: 5 V supply low.
Premier AL power supply indicator: BATT
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Battery fault.
Premier AL power supply indicator: CHARGE
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Charger fault.
Premier AL: D.FLT (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Data Fault: the analogue value reported by the device is not valid.
Premier AL: DADDR (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Double Address: two or more devices exist with the same address.
Premier AL power supply indicator: EARTH
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Earth fault, printed in the manual as “Earth fault (disabled)”; the diagram beside it shows the earth fault monitoring link/disable jumper.
Premier AL: FUSE FAILED (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Auxiliary power supply fuse failed.
Premier AL power supply indicator: L/BATT
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Low battery voltage (below 19 V).
Premier AL: LINE FAULT (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Open circuit fault detected in the loop cable. This may be due to an operation of short circuit isolators.
Premier AL power supply indicator: MAIN
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Input from the SMPS out of tolerance.
Premier AL power supply indicator: PROC
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: P.S.E. processor fault.
Premier AL power supply indicator: PSU OK
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Power supply healthy; the indicator switches off for 1 second every 30 seconds during the battery discharge test.
Premier AL: R.FLT (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Remote Fault at the address indicated.
Premier AL: RMVD (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Removed: the loop device is not responding.
Premier AL: system fault
Per the manual, in the event of a complete system failure a system fault is indicated: the SYSTEM FAULT and GENERAL FAULT LEDs illuminate and all other LEDs are extinguished; the internal buzzer sounds continuously; the LCD backlight switches off and the text, which shows the last condition, should be ignored; local alarm circuits are silenced if active; all loop devices remain in the condition they were in when the fault occurred, so some sounders may remain active. The manual warns that the system is completely inactive. User action: call your service engineer immediately. Service engineer actions listed: open the outer door, operate the SYSTEM FAULT RESET switch and then the PROCESSOR RESET switch on the motherboard, and observe that the panel restarts and shows the POWER UP DELAY message; if it does not restart properly the panel requires replacement.
Premier AL: fault condition
Per the manual, a fault is indicated if any part of the system enters an abnormal condition. The COMMON FAULT LED pulses (and the ALARM FAULT/DISABLEMENT LED also pulses if the fault is with an alarm circuit), the internal buzzer sounds continuously, the LCD displays details of the event (for example a zone number with OPT FAULT and the device location), and the event is printed if a printer is fitted. During a fault condition events of lower priority are suppressed. User actions listed: switch the access controls keyswitch on, press SILENCE BUZZER (the FAULT and BUZZER SILENCED LEDs go steady), investigate and rectify the cause, and when it is cleared press RESET to return the system to the quiescent condition.
Premier AL power supply indicator: THERM
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Thermistor fault.
Premier AL: W.TYPE / WTYPE (LCD message)
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Wrong Type: the device at this address is different from that configured for the address.
One question, answered from the fault records above. If they don't cover it, we'll say so. Sign up free for 5 questions a day across every panel.
Records marked “sourced — not yet independently verified” carry a real citation but have not yet completed formal review. Always confirm against the manufacturer's current documentation before acting on site.
Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.