Alarm Confirm Input Open
Not yet verifiedOpen circuit at Alarm Confirmation input
Circuit broken at input 'Alarm Confirmation'.
41 fault records for this panel, each labelled with its review status and, where one is cited, the source document it comes from.
41 records
Open circuit at Alarm Confirmation input
Circuit broken at input 'Alarm Confirmation'.
Short circuit at Alarm Confirmation input
Short circuit detected at input 'Alarm Confirmation'.
Battery internal resistance too high
High value (Ri>0.3Ω) of the battery internal resistance. Replace the battery immediately.
Standby battery missing
The accumulator battery is missing.
Standby battery discharged
The accumulator battery is discharged.
Fault in the detector
Fault in the detector.
Charging unit failed
The charging unit is failed.
Dirty detector chamber
Dirty detector chamber.
More than one device sharing a loop address
More than one device with the same address in the loop.
Duplicate panel number on the network
Doubling of the panel number, when two or more panels are connected in a network.
Resistive connection to earth
Resistive connection between some signals and earth, below 10kΩ.
SIMPO: EXT Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Extinguishing output. The manual gives no cause or action for this message.
Short circuit at Extinguishing output
Short circuit detected at Extinguishing output.
SIMPO: Fault Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fault output. The manual gives no cause or action for this message.
Short circuit at Fault output
Short circuit detected at Fault output.
Open circuit at Protection Panel Fault input
Circuit broken at input 'Protection Panel Fault'.
Short circuit at Protection Panel Fault input
Short circuit detected at input 'Protection Panel Fault'.
SIMPO: Fire Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fire output. The manual gives no cause or action for this message.
Short circuit at Fire output
Short circuit detected at Fire output.
FLASH memory error detected
FLASH Memory error is detected.
Event log file lost or damaged
The log file event is lost or damaged.
Loop wiring broken
The loop is broken.
Loop device not responding
The device does not respond (lost or damaged).
Fault in a loop device input
Fault in loop device input.
Fault in a loop device output
Fault in loop device output.
Unexpected device type detected at address
A different than the expected type of device has been detected at the address.
Short circuit detected in the loop
Short circuit detected in the loop.
Device with no address number applied
There is a device without an address number (a device with address 0 is applied).
SIMPO: New Loop Devices Found
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: New loop devices are found in system configuration. The manual gives no cause or action for this message.
SIMPO: New Periphery Devices Found
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: New periphery devices are found in the system configuration. The manual gives no cause or action for this message.
Fault in the connection with another networked panel
Fault in the connection with another panel, when two or more panels are connected in a network.
Peripheral device not responding
The device is not responding (the device is lost or failed).
Wrong peripheral device type at address
A periphery device with different type is found on the address.
Open circuit at Protection Alarm Confirmation input
Circuit broken at input 'Protection Alarm Confirmation'.
Short circuit at Protection Alarm Confirmation input
Short circuit detected at input 'Protection Alarm Confirmation'.
Extinguishing panel failure
The extinguishing panel failure.
RAM memory error detected
RAM Memory error is detected.
Open circuit at Sounder 1 output
Circuit broken at Sounder 1 output.
Short circuit at Sounder 1 output
Short circuit detected at Sounder 1 output.
Open circuit at Sounder 2 output
Circuit broken at Sounder 2 output.
Short circuit at Sounder 2 output
Short circuit detected at Sounder 2 output.
One question, answered from the fault records above. If they don't cover it, we'll say so. Sign up free for 5 questions a day across every panel.
Records marked “sourced — not yet independently verified” carry a real citation but have not yet completed formal review. Always confirm against the manufacturer's current documentation before acting on site.