Advanced Electronics Axis EN fault codes

5 fault records for this panel, each labelled with its review status and, where one is cited, the source document it comes from. Advanced Axis EN EN 54-13 compliant analogue addressable fire panel.

Fault codes and messages

5 records

DEVICE MISSING

Source-checked

Device not found during Loop Auto Learn

During the Loop Auto Learn process, the panel cannot communicate with a device that was previously programmed onto the loop. Auto Learn suspends and a pop-up prompts the engineer to keep or delete the missing device (individually, or all missing devices at once). If the device is kept, the panel reports a fault condition until it is reconnected; if deleted, all its prior programming (sensitivity, text, zone, action) is cleared.

Dirty

Source-checked

Device flagged dirty during Loop Calibrate

Running Loop – Calibrate requests each loop device's internal drift/contamination value. If the value returned by a device exceeds a preset limit, the panel flags a "Dirty" fault against that specific device. The manual does not give the numeric threshold or a remedy; drift values can also be downloaded to the Service Tool.

EARTH FAULT

Source-checked

Earth fault

An Earth Fault shown on the panel display. Whether the panel shows an Earth Fault during normal operation is set by the Earth Fault Notification parameter (manual section 3.3.18.7), toggled with the tick button.

Verified against a cited sourceAxis EN Product Manual (680-165V-07), p. 54

Service Due Fault

Source-checked

Scheduled service date reached

The panel can hold a programmed "Service Due Date". When that date is reached, the panel enters a fault condition to alert the site operator that a service visit is overdue, and the status display shows the configured service telephone number whenever a fault condition is accepted. The fault clears automatically as soon as a new service due date is entered — no manual fault-clear step is described.

TYPE CHANGE

Source-checked

Device type does not match the type programmed at that address

During Loop Auto Learn, the panel finds a device of a different type fitted at an address than the type originally programmed there — the manual gives the example of a heat detector installed in place of an optical smoke detector. The engineer is prompted to accept or reject the new device type (individually, or all at once). Accepting reconfigures that address to the new device with initial default settings; rejecting keeps the original device's programming and the panel reports a fault condition until a device of the correct type is reconnected at that address.

Ask about the Advanced Electronics Axis EN — free, no account

One question, answered from the fault records above. If they don't cover it, we'll say so. Sign up free for 5 questions a day across every panel.

Recorded standards

standards
EN 54-2,EN 54-4

Records marked “sourced — not yet independently verified” carry a real citation but have not yet completed formal review. Always confirm against the manufacturer's current documentation before acting on site.

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.