Skip to main content

Haes Systems

Official sources checked

Fire alarm control equipment represented from Haes Systems product information.

Reviewed products
3
Panel records
6
Verified faults
40
Reviewed parts
0

Official resource links last checked July 19, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Fire alarm control equipment, manufacturer product information
Known names
Haes Systems, Haes

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Lifecycle not classified

ELANNo lifecycle claim made
ESENTONo lifecycle claim made
TechnikNo lifecycle claim made

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Control PanelSource-checked

Esprit Apollo 1-2 Loop Apollo Protocol Panel

One-to-two-loop analogue addressable control panel for the documented Apollo protocol device range.

InterfaceSource-checked

Esprit BMS Communications Card

Plug-in building-management communications interface for the Esprit family.

Repeater PanelSource-checked

Esprit-A Repeater

Networked full-control repeater for Esprit-A fire alarm control panels.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 1 shown
Product catalogueOfficialLink checked

Fire alarm control equipment

Published by Haes Technologies

Incognito summary

Use this official Haes Technologies resource as a primary route to products information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
checking current product information, variants and manufacturer supplied downloads
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
Haes Systems product and support resources
Checked Sep 30, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

No manufacturer specific article has passed the current publication review. Official resources remain available above.

Source reviewed records

Related fault records

View fault records
Esprit Apollo Addressable • Battery high impedance fault (Batt Hi Z)Battery high impedance fault: resistance above 1 ohmThe power supply specification lists the battery high impedance fault (Batt Hi Z) as resistance above 1 ohm, with a 1-hour reporting time.Esprit Apollo Addressable • General Fault LED pulsing (fault condition)Fault condition: display shows number and nature of faultsWhen the panel detects a fault the display indicates the number and nature of the fault(s), the internal buzzer sounds an intermittent tone and the amber General Fault LED pulses, with any other specific Fault LEDs lit. Scroll the list with the arrow keys. Mute Buzzer silences the buzzer and turns the General Fault LED steady. Faults are non-latching (except System Fault) and clear automatically when remedied, or press Reset System to clear. A silenced buzzer re-sounds when a new fault occurs.Esprit Apollo Addressable • Loop fault: short circuit or interruptionLoop transmission path faultIf a fault occurs on a transmission path (short circuit or interruption), the manual says the function of the remaining operational devices is re-established within 300 seconds of the fault, compliant with EN 54-2 clause 12.5.Esprit Apollo Addressable • Power Supply Fault LEDPower supply fault on mains input or batteryThe Power Supply Fault LED pulsing indicates a power supply fault on the mains power input or battery. Steady indicates the same fault with the buzzer muted.Esento Excel 2-12 Zone • Power supply fault on connecting mains before batteriesPower Supply fault for up to 1 minute at power-upIf the mains is connected before the batteries, the panel shows a Power Supply fault for up to 1 minute until the monitoring cycle has finished polling. The manual says this is normal, and to check connections if the fault does not clear after 1 minute.Esprit Apollo Addressable • Power Supply Fault on connecting mains before batteriesPower Supply Fault for up to 1 minute at power-upIf the mains is connected before the batteries, the panel shows a Power Supply Fault for up to 1 minute until the monitoring cycle has finished polling. The manual says this is normal, and to check connections if the fault does not clear after 1 minute.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 184 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.