Skip to main content

Notifier by Honeywell

Official sources checked

Fire detection control equipment documented by Honeywell Notifier product resources.

Reviewed products
3
Panel records
3
Verified faults
98
Reviewed parts
0

Official resource links last checked August 4, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Addressable control panels, networked systems, official specifications
Known names
Notifier by Honeywell, Notifier, Notifier Fire Systems

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Current products

Also found as ID 3000

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Control PanelSource-checked

ID3000

Modular addressable fire alarm control panel family documented in NOTIFIER system design resources.

Io ModuleSource-checked

M701E Single Output Module

Addressable single-output module providing a monitored circuit for polarised loads or an unsupervised switched output, with selectable loop isolation.

Control PanelSource-checked

Pearl

Addressable fire detection control system documented in the official NOTIFIER specification library.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 5 shown
Official websiteOfficialLink checked

NOTIFIER by Honeywell (products and resources)

Published by Honeywell

Incognito summary

Use this official Honeywell resource as a primary route to website information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
starting with the manufacturer's current product and service information
Intended audience
engineers, specifiers, maintainers and system owners
Product range covered
Notifier by Honeywell product and support resources
Checked Nov 4, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
ID50 / ID60 • 6 MONTHS TO CELL LIFE EXPIRYID50/60: 6 MONTHS TO CELL LIFE EXPIRYMessage shown on the ID50/ID60 panel. The manual's Appendix 3 gives the meaning as: The Carbon Monoxide (CO) cell of a SMART 4 multi-criteria sensor has 6 months to end of life. Action listed in the manual: Record in site log book.ID3000 • Aux. Output X FaultAux. Output X FaultParameterised message covering auxiliary outputs 1 and 2 (X = 1 or 2), as printed in the source ('Aux. Output 1 Fault'; 'Aux. Output 2 Fault'). Indicates a failure of the auxiliary drive circuits, not the attached cables. Action: If the fault is on either circuit, change the Base PCB (Kit PN: 020-568).ID50 / ID60 • AUXILIARY SUPPLY FAULTID50/60: AUXILIARY SUPPLY FAULTMessage shown on the ID50/ID60 panel. The manual's Appendix 3 gives the meaning as: A fault with the auxiliary supply has been detected. Action listed in the manual: Check the auxiliary voltage and any associated wiring.ID50 / ID60 • BAD REPLY FROM DEVICEID50/60: BAD REPLY FROM DEVICEMessage shown on the ID50/ID60 panel. The manual's Appendix 3 gives the meaning as: Corrupted communication has been detected between the panel and a loop device. Action listed in the manual: Replace loop device. If problems persist the base board will need to be replaced.ID50 / ID60 • BATTERY CHARGER FAILUREID50/60: BATTERY CHARGER FAILUREMessage shown on the ID50/ID60 panel. The manual's Appendix 3 gives the meaning as: The integral battery charger has failed and the batteries are no longer being charged. Action listed in the manual: Replace base board.ID50 / ID60 • BATTERY DISCHARGEDID50/60: BATTERY DISCHARGEDMessage shown on the ID50/ID60 panel. The manual's Appendix 3 gives the meaning as: The output voltage of the batteries has fallen below the minimum required for correct panel operation. Action listed in the manual: Check the condition of the batteries.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 186 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.