Skip to main content

Gent by Honeywell

Official sources checked

Fire detection systems covered through Honeywell's official Gent brand resources.

Reviewed products
7
Panel records
3
Verified faults
23
Reviewed parts
0

Official resource links last checked August 4, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Addressable fire detection, control panels, manufacturer technical resources
Known names
Gent by Honeywell, Gent

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Current products

Vigilon PlusView status source
Vigilon Compact PlusView status source

Also found as Compact Plus, Vigilon Compact

Also found as S Quad, SQuad

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Control PanelSource-checked

Nano

Compact Gent control panel supporting the manufacturer documented Vigilon loop device range.

Detection DeviceSource-checked

S-Quad

Gent analogue addressable detection and alarm device range presented in the manufacturer product portfolio.

InterfaceSource-checked

S4-34401 Single Channel Mains Switching Interface

Boxed, loop-powered single-channel input/output mains-switching interface with configurable input interpretation and normally-open or normally-closed output contacts.

Control PanelSource-checked

Vigilon Compact Plus

Compact addressable fire alarm control panel family listed in Gent current product information.

Control PanelSource-checked

Vigilon Plus

Addressable fire alarm control panel family listed in Gent current product information for standalone and networked systems.

Repeater PanelSource-checked

VIGPLUS-RPT Vigilon Plus Loop Controlled Repeater

Fully functional Vigilon Plus repeater with control, configurable for site-wide or local indication and connected on standard loop cabling.

Control PanelSource-checked

Xenex

Conventional fire alarm control panel range listed in Gent product information.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 9 shown
Technical supportOfficialLink checked

Technical knowledge centre

Published by Honeywell

Incognito summary

Use this official Honeywell resource as a primary route to support information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
finding the manufacturer's technical support routes and approved support material
Intended audience
commissioning, service and maintenance engineers
Product range covered
Gent by Honeywell product and support resources
Checked Nov 2, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
Gent by Honeywell Vigilon Compact • Battery dischargedControl panel battery fully dischargedThe battery supply at the Control Panel is fully discharged. Check the battery and replace if necessary.Vigilon • Battery discharged nVigilon: Battery discharged nMessage shown on the Vigilon panel. Meaning per the manual: the battery supply to the control panel has been fully discharged. Indications listed: Fault and Power fault. Action listed in the manual: check the battery and replace if necessary.Gent by Honeywell Vigilon Compact • Battery disconnectedControl panel battery disconnectedThe battery supply to the Control Panel has been disconnected. Reconnect the battery.Vigilon • Battery disconnectedVigilon: Battery disconnectedMessage shown on the Vigilon panel. Meaning per the manual: the battery supply to the control panel has been disconnected. Indications listed: Fault and Power fault. Action listed in the manual: reconnect the battery.Vigilon • Device Battery faultVigilon: Device Battery faultMessage shown on the Vigilon panel. Meaning per the manual: the battery supply at an interface unit, repeat panel or mimic panel has failed the load test. Indications listed: Fault. Action listed in the manual: check the battery and replace if necessary.Gent by Honeywell Vigilon Compact • Device Battery faultBattery load test failed at an interface unit, repeat panel or mimic panelThe battery supply at an interface unit, repeat panel or mimic panel has failed the load test. Check the battery and replace if necessary.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 186 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.