Skip to main content

Advanced

Official sources checked

Fire alarm control equipment with official product support and technical documentation.

Reviewed products
11
Panel records
3
Verified faults
36
Reviewed parts
0

Official resource links last checked August 4, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Control panels, networked systems, manufacturer support documentation
Known names
Advanced, Advanced Electronics

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Current products

Also found as MX Pro, MX Pro 5, MXPro5, MX Pro five

Also found as AxisEN

Also found as Axis Go

Legacy products

Also found as MX Pro 4, MXPro4, MX Pro four

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Control PanelSource-checked

Axis EN

Modular addressable fire alarm control system documented by Advanced for standalone and networked applications.

Control PanelSource-checked

AxisGo

Single loop addressable fire alarm panel documented in the Advanced product portfolio.

Repeater PanelSource-checked

MX-5020 MxPro 5 Remote Control Terminal

Full-control remote terminal that reproduces the MxPro 5 graphical interface on the documented Advanced peer-to-peer panel network.

Networking ProductSource-checked

MXP-503 Standard Network Card

Standard network card for connecting MxPro 5 control panels, remote terminals and network peripherals over a fire-resistant two-core network.

Networking ProductSource-checked

MXP-509 Fault Tolerant Network Card

Fault-tolerant network card for MxPro 5 systems, monitored for open- and short-circuit faults and designed to retain communications after a single inter-node fault.

Loop CardSource-checked

MXP-567 Nittan Loop Driver Card

MxPro 5 loop driver card for the documented Nittan Evolution addressable detection protocol.

Loop CardSource-checked

MXP-568 Apollo / Hochiki / Argus Loop Driver Card

MxPro 5 loop driver card for documented Apollo, Hochiki ESP and Argus Vega addressable detection protocols.

Power SupplySource-checked

MXP-650 2.5A Boxed Power Supply Unit

Boxed 24 V power-supply and battery-charger unit with dual monitored outputs and deep-discharge protection for fire-alarm and AOV applications.

Power SupplySource-checked

MXP-651 5.0A Boxed Power Supply Unit

Boxed 24 V power-supply and battery-charger unit with dual monitored outputs and deep-discharge protection for fire-alarm and AOV applications.

Control PanelSource-checked

MxPro 5

Addressable fire alarm control panel available in documented one, two, four and eight loop formats, with manufacturer supplied engineering tools and networking options.

SoftwareSource-checked

PC-NET-022 ConfigTool

Windows configuration software for Advanced MxPro and Go fire panels, including cause-and-effect programming, virtual panel display and remote diagnostics.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 10 shown
Official videosOfficialRedirect detected

Advanced Fire official YouTube channel with instructional films and webinars

Published by Advanced

Incognito summary

Use this official Advanced resource as a primary route to videos information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
finding manufacturer published demonstrations, webinars and technical videos
Intended audience
engineers, apprentices and technical managers
Product range covered
Advanced product and support resources

This link is retained while its current destination is reviewed. Incognito does not remove official resources automatically.

Checked Nov 2, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
Advanced MxPro 5 • AUX LOAD TOO HIGHAuxiliary Output Load Too HighThe panel's auxiliary 24V output current draw is above its normal operating range (0-500mA) — an overload on equipment powered from the AUX terminals. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22-23, Document 680-166 Revision 04), which lists "Aux Load" as one of the panel's monitored internal circuits with a "Too High" possible state.Advanced MxPro 4 • Aux Supply Too HighAuxiliary supply current above expected rangeFrom the panel's own "View - Panel" diagnostic table: Aux Supply is monitored 0mA-500mA; the panel reports Too High when the current exceeds the expected range.Advanced MxPro 5 • BATTERY LOWBattery Voltage Too LowThe standby battery voltage has dropped below the panel's normal operating band (nominally 27.6V). From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the possible circuit states (Normal / Too High / Too Low / Open Circuit / Short Circuit) the panel reports for this circuit. This is the User Manual, not the fuller Installation and Commissioning Manual (Document 680-165), so it confirms the condition and its general meaning but not every underlying wiring-level cause.Advanced MxPro 4 • Battery Too HighStandby battery voltage above expected rangeFrom the panel's own "View - Panel" diagnostic table: Battery is monitored 0V-30V, normal >25.0V; the panel reports Too High when the reading exceeds the expected range.Advanced MxPro 5 • BATTERY TOO HIGHBattery Voltage Too HighThe standby battery voltage is above the panel's normal operating band. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the possible circuit states (Normal / Too High / Too Low / Open Circuit / Short Circuit) the panel reports for this circuit. This is the User Manual, not the fuller Installation and Commissioning Manual (Document 680-165), so it confirms the condition and its general meaning but not every underlying wiring-level cause.Advanced MxPro 4 • Battery Too LowStandby battery voltage below expected rangeFrom the panel's own "View - Panel" diagnostic table: Battery is monitored 0V-30V, normal >25.0V under full load. Per the manual's own note, the voltage shown is measured under full load conditions; if it falls below 23.0V under full load test, the panel indicates Too Low.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 186 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.