Skip to main content

Fike

Official sources checked

Fire detection control equipment represented from Fike's official product information.

Reviewed products
3
Panel records
6
Verified faults
39
Reviewed parts
0

Official resource links last checked July 19, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection
Typical engineering use
Fire detection, control equipment, manufacturer product documentation
Known names
Fike, Fike Safety Technology

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Lifecycle not classified

Cheetah XiNo lifecycle claim made
DuonetNo lifecycle claim made
TwinflexNo lifecycle claim made

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Control PanelSource-checked

CIE-A-200 Addressable Fire Alarm Control Panel

Single-loop addressable fire alarm control panel for up to 200 Fike addressable devices; explicitly superseded by CIE-A-400.

Control PanelSource-checked

CIE-A-400 1-2 Loop Addressable Fire Alarm Control Panel

One-loop addressable fire alarm control panel expandable to two loops using the documented 540-0003 loop card.

Control PanelSource-checked

TWINFLEXpro2 4 Zone Control Panel

Four-zone intelligent two-wire analogue non-addressable fire alarm control panel.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

1 of 1 shown
Product catalogueOfficialLink checked

Fire alarm control panels

Published by Fike

Incognito summary

Use this official Fike resource as a primary route to products information. Confirm that any document or download matches the installed product, revision and local project requirements before relying on it.

Useful for
checking current product information, variants and manufacturer supplied downloads
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
Fike product and support resources
Checked Sep 30, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
CIE-A-200 • Addressable circuit: -ve open circuitCIE-A-200: Addressable circuit: -ve open circuitPer the manual, if the system faces a loop -ve open circuit during initialisation, initialisation does not fail at that point but continues to the end of the loop and all devices are operational (as long as no other faults exist). A message of Addressable circuit: -ve open circuit is displayed, but the panel cannot detect where the open circuit is. To locate it, stop the loop, disconnect loop end 2, wait at least 3 minutes and reinitialise: initialisation then fails at that point and Loop not complete is displayed. The loop must be reinitialised to clear the fault, always waiting at least 3 minutes between stopping a loop and reinitialising.Quadnet • Addressable circuit: -ve open circuitQuadnet: Addressable circuit: -ve open circuitPer the manual, if the system faces a loop -ve open circuit during initialisation, initialisation continues to the end of the loop and all devices are operational (as long as no other faults exist). A message of Addressable circuit: -ve open circuit is displayed, but the panel cannot detect where it is. To locate it, stop the loop, disconnect loop end 2, wait at least 3 minutes and reinitialise: initialisation then fails at that point and Loop not complete is displayed. The loop must be reinitialised to clear the fault.CIE-A-200 • Device faults during initialisationCIE-A-200: Device faults during initialisationPer the manual, if the system detects a device fault or fire activation during initialisation, initialisation does not fail at that point. Beyond certain limits initialisation will fail and the various fault or fire activations are displayed. Deal with the events before reinitialising: first investigate and rectify fire activations (from unreset call points to contaminated multipoint detectors), then fault conditions (from Input open circuit to a multipoint detector with its optical chamber loose, indicating signal low). Devices or chambers should be removed or replaced only with the loop stopped.Quadnet • Device Quantity MismatchQuadnet: Device Quantity MismatchPer the manual, after initialising the loop, if the number of devices initialised does not match the number programmed, a DEVICE QUANTITY MISMATCH screen appears showing the number found and programmed. A mismatch occurs if devices have been removed or added and the changes have not been updated in the OSP and downloaded into the panel, or if the loop was initialised too quickly after it was stopped (stop the loop and wait at least 5 minutes before reinitialising). On a new panel a mismatch is likely, because it will have been tested in the factory with various configurations.CIE-A-200 • Device Quantity MismatchCIE-A-200: Device Quantity MismatchPer the manual, a device mismatch occurs if a device or devices have been physically removed from or added to the system and the changes have not been updated in the OSP and downloaded into the panel; the panel expects to find the original number of devices downloaded to it. Check the site information for changes and compare with the OSP file. Another cause is initialising the loop too quickly after it was stopped: if a device has not powered down completely it may be missed and cause a mismatch. Stop the loop and wait at least 5 minutes before reinitialising.CIE-A-400 • DEVICE QUANTITY MISMATCHDevice quantity mismatchThe number of devices found during CIE-A-400 loop initialisation does not match the number programmed in the approved OSP configuration.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 184 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.