Skip to main content

C-TEC

Official sources checked

Fire alarm and life safety equipment covered through C-TEC's official support documentation.

Reviewed products
41
Panel records
6
Verified faults
53
Reviewed parts
0

Official resource links last checked July 29, 2026.

Manufacturer overview

Documented engineering coverage

Incognito records the manufacturer identity, official resources and supported product families shown on this page. Coverage confirms catalogue evidence only. It does not imply manufacturer approval, product compatibility or access to restricted support.

Product categories
Fire detection, Voice alarm
Typical engineering use
Addressable panels, conventional panels, manufacturer support documentation
Known names
C-TEC, C TEC

Common engineer searches

Continue in engineering search

Products supported by Incognito

Documented product families

Lifecycle labels are shown only when a current official page or manufacturer lifecycle notice supports the classification. All other product names remain unclassified.

Current products

Also found as XFP CAST

Also found as ZFP CAST

Also found as C TEC CAST, CTEC CAST

Also found as CFP conventional

Source reviewed technical data

Structured product records

These records expose only supported specifications and retain missing values rather than filling them by assumption.

Compare recorded products
Networking ProductSource-checked

AFP711 XFP Network Driver Card

Optional RS485 network driver card for XFP one/two-loop 32-zone panels; supplied in XFP repeaters.

Networking ProductSource-checked

BF356 ZFP Fibre Optic Transceiver

ZFP RS485-to-duplex multimode fibre transceiver for documented Hi-Net fibre links.

Power SupplySource-checked

BF360-24

External EN 54-4 power supply identified by C-TEC as a suitable supply example for the ZFP Compact Controller.

Power SupplySource-checked

BF560-12 Boxed Power Supply

Boxed 12 V, 2 A C-TEC power supply documented as the required supply for BF356 fibre transceivers.

Detection DeviceSource-checked

CA402 CAST Programmable Heat Detector

Programmable CAST heat detector with onboard short-circuit isolator for XFP and ZFP CAST panels.

AccessorySource-checked

CA408 CAST Detector Base

Detector base for compatible CAST and CAST-PRO detectors, with remote-indicator terminals, locking mechanism and identification tag.

Detection DeviceSource-checked

CA414 CAST Programmable Multi-Sensor

Programmable CAST smoke-and-heat multi-sensor with five documented operating modes and onboard isolator.

Detection DeviceSource-checked

CA416 CAST Optical Smoke Detector

CAST optical smoke detector with onboard short-circuit isolator for XFP and ZFP CAST panels.

Call PointSource-checked

CA470 CAST Red Manual Call Point

Universal surface- or flush-mount red CAST manual call point with resettable element and onboard isolator.

Call PointSource-checked

CA47067 CAST IP67 Red Manual Call Point

IP67 surface-mount red CAST manual call point with onboard short-circuit isolator.

SoftwareSource-checked

CA507 XFP CAST/Apollo Programming Tools

Programming kit for C-TEC XFP CAST and Apollo protocol panels; XFP507 is the separate Hochiki ESP kit.

Io ModuleSource-checked

CA730 CAST Input Output Module

CAST input/output module combining switch-monitor, zone-monitor and relay-output functions with onboard isolator.

Io ModuleSource-checked

CA731 CAST Mains Switching Input Output Module

CAST mains-switching input/output module with onboard loop isolator.

InterfaceSource-checked

CA732 CAST Zone Monitor Module

Single-zone CAST conventional-zone monitor with onboard short-circuit isolator.

Io ModuleSource-checked

CA734 CAST Mini I/O Unit

Miniature CAST I/O unit with monitored input, relay output and onboard isolator.

InterfaceSource-checked

CA738 CAST Sounder Control Module

CAST interface providing one monitored circuit for conventional sounders or VADs.

InterfaceSource-checked

CA739 CAST 4-8 Way Sounder Controller

Four-circuit CAST sounder controller expandable to eight circuits, documented only for ZFP CAST panels.

InterfaceSource-checked

CA740 4-Way Conventional Zone to CAST Converter

Converter for migrating conventional detection branches to a CAST addressable system.

InterfaceSource-checked

CA742 CAST Loop Resistance Tester

End-B loop resistance tester documented only for ZFP CAST systems.

AccessorySource-checked

CAPROG CAST Handheld Device Programmer

Battery-powered handheld programmer and tester for assigning user IDs to CAST field devices and checking device response.

Detection DeviceSource-checked

CP402 CAST-PRO Heat Detector

CAST-PRO heat detector with documented A1R and A2 modes and onboard short-circuit isolator.

Detection DeviceSource-checked

CP411 CAST-PRO CO Smoke and Heat Multi-Sensor

CAST-PRO carbon-monoxide, smoke and heat multi-sensor with onboard short-circuit isolator.

Detection DeviceSource-checked

CP414 CAST-PRO Smoke and Heat Multi-Sensor

CAST-PRO smoke-and-heat multi-sensor with eight documented operating modes and onboard isolator.

Detection DeviceSource-checked

CP416 CAST-PRO Smoke Detector

CAST-PRO smoke detector with two documented sensitivity modes and onboard short-circuit isolator.

Detection DeviceSource-checked

CPDUCT/OPT CAST-PRO Duct Detector

CAST-PRO duct detector supplied with CP416 smoke detector and CA408 base for XFP and ZFP CAST systems.

Control PanelSource-checked

XFP 1/2 Loop 32 Zone

One- or two-loop, 32-zone XFP addressable fire alarm control panel.

Control PanelSource-checked

XFP Single Loop 16 Zone

Single-loop, 16-zone XFP addressable fire alarm control panel.

Control PanelSource-checked

XFP502/CA

Two-loop, 32-zone XFP control panel using C-TEC CAST detection protocol.

Repeater PanelSource-checked

XFP510-16

Sixteen-zone XFP repeater supporting a network of up to eight panels or repeaters.

Networking ProductSource-checked

XFP761 XFP Network Driver Card

Network driver card documented for XFP single-loop 16-zone panels.

Loop CardSource-checked

Z02LOOP/CA ZFP CAST Two-Loop Expansion PCB

Two-loop CAST expansion PCB providing loops 3 and 4 for compatible two-loop-main-PCB ZFP CAST panels.

Io ModuleSource-checked

Z13 ZFP 8-Way Input Output PCB

Eight-channel ZFP A-BUS monitored-input/open-collector-output PCB.

Io ModuleSource-checked

Z14 ZFP 16-Way Input Output PCB

Sixteen-channel ZFP A-BUS monitored-input/open-collector-output PCB.

Io ModuleSource-checked

Z15 ZFP 4-Way Conventional Sounder PCB

Four-circuit ZFP A-BUS conventional-sounder PCB requiring an external EN 54-4 power supply.

Io ModuleSource-checked

Z16 ZFP 4-Zone 2-Sounder PCB

ZFP A-BUS PCB with four conventional detection zones and two conventional sounder circuits.

Control PanelSource-checked

ZFP CAST Standard Cabinet Panel

Touchscreen-controlled C-TEC CAST addressable fire panel in the standard cabinet format.

Repeater PanelSource-checked

ZREP1S/CA ZFP Compact Controller

Surface-mount compact ZFP CAST controller for connection to a ZFP Hi-Net network.

SoftwareSource-checked

ZTOOLS ZFP Programming Tools

C-TEC toolkit for programming and configuring supported ZFP fire panels.

Direct from the manufacturer

Official resources

Each record includes an original Incognito summary before the external link. Incognito does not host or mirror the linked material.

4 of 9 shown
Product catalogueOfficialLink checked

CAST addressable fire alarm system

Published by C-TEC • CAST

Incognito summary

Use this official C-TEC resource as the primary starting point for CAST. It is most useful for products information and should be checked against the exact installed model, document revision and site configuration.

Useful for
checking current product information, variants and manufacturer supplied downloads for CAST
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
CAST
Checked Oct 30, 2026Open official resource
Product catalogueOfficialLink checked

CFP conventional fire panels

Published by C-TEC • CFP

Incognito summary

Use this official C-TEC resource as the primary starting point for CFP. It is most useful for products information and should be checked against the exact installed model, document revision and site configuration.

Useful for
checking current product information, variants and manufacturer supplied downloads for CFP
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
CFP
Checked Oct 30, 2026Open official resource
Product catalogueOfficialLink checked

XFP CAST addressable fire panel

Published by C-TEC • XFP

Incognito summary

Use this official C-TEC resource as the primary starting point for XFP. It is most useful for products information and should be checked against the exact installed model, document revision and site configuration.

Useful for
checking current product information, variants and manufacturer supplied downloads for XFP
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
XFP
Checked Oct 30, 2026Open official resource
Product catalogueOfficialLink checked

ZFP CAST addressable fire panel

Published by C-TEC • ZFP

Incognito summary

Use this official C-TEC resource as the primary starting point for ZFP. It is most useful for products information and should be checked against the exact installed model, document revision and site configuration.

Useful for
checking current product information, variants and manufacturer supplied downloads for ZFP
Intended audience
design, installation, commissioning and maintenance engineers
Product range covered
ZFP
Checked Oct 30, 2026Open official resource

Documentation, videos and downloads remain the property of their respective manufacturers.

Incognito technical guidance

Search all related content

Source reviewed records

Related fault records

View fault records
MFP Range (4-28 Zone) Conventional Fire Alarm Panel • Battery/Power Supply FaultPermanent Battery/Power Supply FaultCheck: (1) the MAINS ON light is illuminated — if not, check the mains supply and fuse next to the transformer; (2) the battery leads are connected the correct way round (reversed leads blow the battery fuse F5 and can cause a permanent, non-resettable power fault); (3) two 12V batteries of the correct size are connected in series; (4) the wiring loom is properly seated on PL4; (5) the transformer leads are properly connected. If the fault persists with the mains light lit, the batteries may be heavily discharged or have failed — try a known-good, fully charged pair.C-TEC XFP • Device missingDevice missing from loopLoop learn cannot find a device expected by the stored configuration.C-TEC ZFP • Displaying and clearing fault conditionsZFP: Displaying and clearing fault conditionsPer the manual, when a fault occurs one or more Fault indicators flash yellow, the internal buzzer sounds (if enabled) and the fault button on the touchscreen changes from blue to yellow with the number of faults shown. Pressing it shows the fault type and location; pressing the fault display shows more detail: for device-specific faults the loop number and address. The designated responsible person may silence the internal buzzer (new faults resound it), take steps to have the fault rectified, and note it in the log book. Once faults have been cleared the panel should auto-reset and return to normal; pressing Reset while faults are still present will not clear them, and they will simply re-appear.C-TEC XFP • Double addressDouble address detectedLoop learn has found more than one device using the same address.C-TEC ZFP • DOUBLE ADDRESSDuplicate CAST device addressThe ZFP reports DOUBLE ADDRESS when more than one CAST device uses the same loop address.C-TEC ZFP • Earth faultZFP earth faultThe ZFP earth-fault monitoring circuitry has detected an abnormal system connection to earth.

Engineer questions

Related FAQs

Search FAQs

No FAQ for this manufacturer has completed source review. Search remains available without presenting unreviewed answers as verified guidance.

Technical guidance boundary

Use the exact current manufacturer document for the installed model and revision. Confirm the site configuration, cause and effect, fire strategy, applicable standards and safe isolation procedure before taking action. Incognito does not claim manufacturer endorsement or guarantee a diagnosis.

One connected engineering library

The live technical database contains 30 supported manufacturers, 96 panel records and 186 reviewed product records.

Other manufacturer hubs

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.