Panel fault codes

Fault codes by panel

Search fault records across 49 panels. Each record is labelled with its review status and, where one is cited, the source document and page it comes from.

Searches 608 records across 49 panels — 573 of them source-verified. Signed in, your dashboard fault search covers only the fully source-verified records, on any plan.

Want to test yourself? Try the free daily fault challenge.

30+ partial matches for “C-TEC training”

Nothing matched every word, so these match some of them. Check the record and panel before relying on it.

Protec 6500

Fire Protection Fault

Source-checked

The "Fire Protection Fault" LED on the 6500 panel's indicator strip, covering fire protection outputs (e.g. suppression or protection-related outputs) configured on the system. This is one of the labelled LED indicators…

View on the Protec 6500 page

Ziton ZP2-FR

Fire protection fault

Source-checked

The yellow Fire Protection Fault/Disabled/Test LED indicates a fire protection fault, disablement, or test. A flashing LED indicates a fault; a steady LED indicates a disablement or a test. From the ZP2 Series…

View on the Ziton ZP2-FR page

Zeta Simpo

Fault Protection Panel Input Open

Source-checked

Circuit broken at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

Fault Protection Panel Input Short

Source-checked

Short circuit detected at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

Protection Alarm Confirm Open

Source-checked

Circuit broken at input 'Protection Alarm Confirmation'.

View on the Zeta Simpo page

Zeta Simpo

Protection Alarm Confirm Short

Source-checked

Short circuit detected at input 'Protection Alarm Confirmation'.

View on the Zeta Simpo page

C-TEC XFP

Locating loop open or short circuits: BLINK DETECTOR LEDS

Source-checked

Per the manual, this engineering function momentarily asserts the LED outputs of loop devices in one continual sweep, and is useful for locating open or short circuit faults on the loop wiring. LEDs are asserted step by…

View on the C-TEC XFP page

Haes Systems Esento Excel 2-12 Zone

Zone detector removed

Source-checked

For zones 1 to 4 on the Main PCB, in fault diagnosis mode (press and hold ENTER) the Zone Fault/Disabled/Test LED going off after pressing ENTER, with a slow pulse shown in the table, means a detector has been removed…

View on the Haes Systems Esento Excel 2-12 Zone page

Haes Systems Esento Eclipse 2-4 Zone

Zone detector removed

Source-checked

For zones 1 to 4 on the Main PCB, in fault diagnosis mode (press and hold ENTER) the Zone Fault/Disabled/Test LED going off after pressing ENTER, with a slow pulse shown in the table, means a detector has been removed…

View on the Haes Systems Esento Eclipse 2-4 Zone page

Global Fire Equipment OCTO+

No nodes detected

Source-checked

Given in the source only as an illustrative example ("Example: 'No nodes detected'") of the network status/error text shown by programming function 8-5-3 "Installation Status", which reports the status of the network.…

View on the Global Fire Equipment OCTO+ page

Protec 6500

Alarm Fault

Source-checked

The "Alarm Fault" LED on the 6500 panel's indicator strip. This is one of the labelled LED indicators on the 6500 control panel's front fascia, confirmed directly from Protec's own product photography. The brochure…

View on the Protec 6500 page

Protec 6500

Alarm Routing Fault

Source-checked

The "Alarm Routing Fault" LED on the 6500 panel's indicator strip, covering the alarm signalling/routing path (e.g. to an ARC or monitoring centre). This is one of the labelled LED indicators on the 6500 control panel's…

View on the Protec 6500 page

Protec 6500

Aux Supply Fault

Source-checked

The "Aux Supply Fault" LED on the 6500 panel's indicator strip, covering the panel's auxiliary power supply. This is one of the labelled LED indicators on the 6500 control panel's front fascia, confirmed directly from…

View on the Protec 6500 page

Protec 6500

Loop Drive Processor Fault

Not yet verified

The loop driver processor has reported a fault. Take the reporting panel offline then back online to attempt to clear it; if it persists, report the fault to Protec technical support.

View on the Protec 6500 page

Protec 6500

Network - Duplicate Master

Not yet verified

Two master panels have been detected on the network — either two panels were assigned as master in their configuration data (correct via the PC commissioning software), or a double break in the network wiring left two…

View on the Protec 6500 page

Protec 6500

Network Fault

Source-checked

The "Network Fault" LED on the 6500 panel's indicator strip, covering the panel-to-panel network connection used when multiple 6500 panels are networked together. This is one of the labelled LED indicators on the 6500…

View on the Protec 6500 page

Protec 6500

Power Fault

Source-checked

The "Power Fault" LED on the 6500 panel's indicator strip, covering the panel's own power supply. This is one of the labelled LED indicators on the 6500 control panel's front fascia, confirmed directly from Protec's own…

View on the Protec 6500 page

Protec 6500

System Fault

Source-checked

The "System Fault" LED on the 6500 panel's indicator strip. This is one of the labelled LED indicators on the 6500 control panel's front fascia, confirmed directly from Protec's own product photography. The brochure…

View on the Protec 6500 page

Protec 6100

Aux. Supply Fault (24 V output)

Source-checked

The manual says a fault has been detected with the auxiliary 24 V supply output of the 6100. There may no longer be an auxiliary supply to external devices, or the auxiliary devices are drawing too much current. The…

View on the Protec 6100 page

Protec 6100

Fire link Fault (monitored fire link path)

Source-checked

The manual says a fault has been detected on the monitored fire link path. This may be a wiring fault or a fire link interface fault. The connection to the fire station link is no longer reliable, and expert advice…

View on the Protec 6100 page

Protec 6100

General fault handling

Source-checked

The manual says that when the 6100 detects a fault in any of the critical operating paths it shows it on the front panel display and the internal buzzer pulses slowly. The General Fault indicator is illuminated and is…

View on the Protec 6100 page

Protec 6100

Repeat Panel Fault

Source-checked

The manual says a fault has been detected on a repeat panel connected to the 6100, or the wiring to the repeat panel is faulty. The General Fault indicator is illuminated accompanied by the Repeat Fault indicator.

View on the Protec 6100 page

Protec 6100

Supply Fault

Source-checked

The manual says a fault has been detected in the power supply of the 6100. This may be because the local mains supply has failed, or because the internal stand-by batteries or circuitry are faulty. The General Fault…

View on the Protec 6100 page

Protec 6100

System Faults

Source-checked

The manual says the 6100 performs regular self tests to ensure the software is working correctly. If a fault is detected in software operation a System Fault is declared. It is a latching fault and can only be cleared…

View on the Protec 6100 page

C-TEC CFP (2/4/8 Zone Standard Conventional)

Zone Fault

Source-checked

All zone circuits are monitored for open- and short-circuit faults and detector head removal (unless the zone is in alarm, test or disabled). The relevant Zone Fault light pulses yellow. Access level three fault…

View on the C-TEC CFP (2/4/8 Zone Standard Conventional) page

C-TEC CFP AlarmSense (2/4/8 Zone)

Zone Fault

Source-checked

All zone circuits (up to eight) are monitored for open circuit and short circuit faults and detector head removal, unless the zone is in an alarm condition or is in test or disabled. The relevant Zone Fault light pulses…

View on the C-TEC CFP AlarmSense (2/4/8 Zone) page

Protec 6500

Loop Drive Open Circuit

Not yet verified

The loop has a break in its wiring. The fault threshold is set to 100Ω.

View on the Protec 6500 page

Protec 6500

Loop Drive Overload Fault

Not yet verified

The loop cannot be driven due to an overload condition.

View on the Protec 6500 page

Protec 6500

Loop Drive Parallel Fault

Not yet verified

There is a low resistance between loop '+' and loop '-'. The fault threshold is 200Ω (Issue E) or 120Ω (Issue F). This fault can also occur if more than ten loop device repeater LEDs are turned on at the same time.

View on the Protec 6500 page

Protec 6500

Loop Drive Series Fault

Not yet verified

There is a high resistance in the loop wiring. The fault threshold is 80Ω (Issue E) or 50Ω (Issue F), though the manual adds that "any value greater than 32 is considered high" (no unit given). The loop current…

View on the Protec 6500 page