ESSER by Honeywell FlexES Control

98/99

Source-checked

The FlexES Control local essernet receive buffer has reached 100 percent because one or more network participants have not acknowledged telegrams despite retries. FAQ 1001 treats codes 98 and 99 as one combined…

View on the ESSER by Honeywell FlexES Control page

Notifier by Honeywell ID3000

Battery Failure

Source-checked

These faults indicate the occurrence of one or more of: a. Faulty or disconnected batteries (if discharged batteries are connected, they may remain in Battery Low Voltage for a period until the voltage is raised by the…

View on the Notifier by Honeywell ID3000 page

Notifier by Honeywell ID3000

Battery Low Voltage

Source-checked

These faults indicate the occurrence of one or more of: a. Faulty or disconnected batteries (if discharged batteries are connected, they may remain in Battery Low Voltage for a period until the voltage is raised by the…

View on the Notifier by Honeywell ID3000 page

Notifier by Honeywell ID3000

Fault 74 - RS232\RS485\PRINTER Card displaced

Source-checked

An attempt has been made to remove one of these items while the panel is powered up. Remove power before proceeding.

View on the Notifier by Honeywell ID3000 page

Notifier by Honeywell ID3000

PSU/Charger Fault

Source-checked

These faults indicate the occurrence of one or more of: a. Faulty or disconnected batteries (if discharged batteries are connected, they may remain in Battery Low Voltage for a period until the voltage is raised by the…

View on the Notifier by Honeywell ID3000 page

Zeta Simpo

Alarm Confirm Input Open

Source-checked

Circuit broken at input 'Alarm Confirmation'.

View on the Zeta Simpo page

Zeta Simpo

Alarm Confirm Input Short

Source-checked

Short circuit detected at input 'Alarm Confirmation'.

View on the Zeta Simpo page

Zeta Simpo

Battery High Resistance

Source-checked

High value (Ri>0.3Ω) of the battery internal resistance. Replace the battery immediately.

View on the Zeta Simpo page

Zeta Simpo

Battery Loss

Source-checked

The accumulator battery is missing.

View on the Zeta Simpo page

Zeta Simpo

Battery Low

Source-checked

The accumulator battery is discharged.

View on the Zeta Simpo page

Zeta Simpo

Chamber Fault

Source-checked

Fault in the detector.

View on the Zeta Simpo page

Zeta Simpo

Charger Fault

Source-checked

The charging unit is failed.

View on the Zeta Simpo page

Zeta Simpo

Clean Me Now

Source-checked

Dirty detector chamber.

View on the Zeta Simpo page

Zeta Simpo

Double Address

Source-checked

More than one device with the same address in the loop.

View on the Zeta Simpo page

Zeta Simpo

Double Panel number

Source-checked

Doubling of the panel number, when two or more panels are connected in a network.

View on the Zeta Simpo page

Zeta Simpo

Earth Fault

Source-checked

Resistive connection between some signals and earth, below 10kΩ.

View on the Zeta Simpo page

Zeta Simpo

EXT Output Open

Source-checked

Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Extinguishing output. The manual gives no cause or action for this message.

View on the Zeta Simpo page

Zeta Simpo

EXT Output Short

Source-checked

Short circuit detected at Extinguishing output.

View on the Zeta Simpo page

Zeta Simpo

Fault Output Open

Source-checked

Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fault output. The manual gives no cause or action for this message.

View on the Zeta Simpo page

Zeta Simpo

Fault Output Short

Source-checked

Short circuit detected at Fault output.

View on the Zeta Simpo page

Zeta Simpo

Fault Power AUX

Source-checked

As given in the source's own event table: "Short circuit (the mains power supply is lost)" — the source's wording for this entry is terse and possibly abbreviated; quoted as written rather than expanded.

View on the Zeta Simpo page

Zeta Simpo

Fault Protection Panel Input Open

Source-checked

Circuit broken at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

Fault Protection Panel Input Short

Source-checked

Short circuit detected at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

Fire Output Open

Source-checked

Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fire output. The manual gives no cause or action for this message.

View on the Zeta Simpo page

Zeta Simpo

Fire Output Short

Source-checked

Short circuit detected at Fire output.

View on the Zeta Simpo page

Zeta Simpo

Flash Error

Source-checked

FLASH Memory error is detected.

View on the Zeta Simpo page

Zeta Simpo

GENERAL FAULT

Source-checked

Lights on permanently in case of a fault event in the system.

View on the Zeta Simpo page

Zeta Simpo

Log Fault

Source-checked

The log file event is lost or damaged.

View on the Zeta Simpo page

Zeta Simpo

Loop Break

Source-checked

The loop is broken.

View on the Zeta Simpo page

Zeta Simpo

Loop Device Fault

Source-checked

The device does not respond (lost or damaged).

View on the Zeta Simpo page

Browse by manufacturer

49 panels

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.