Skip to main content
Panel fault codes

Fault codes by panel

Search fault records across 49 panels. Each record is labelled with its review status and, where one is cited, the source document and page it comes from.

Searches 608 records across 49 panels — 573 of them source-verified. Signed in, your dashboard fault search covers only the fully source-verified records, on any plan.

Want to test yourself? Try the free daily fault challenge.

30+ partial matches for “FireClass manuals”

Nothing matched every word, so these match some of them. Check the record and panel before relying on it.

FireClass FC501

24A Output

Source-checked

Shorted 24A Output

View on the FireClass FC501 page

FireClass FC501

24R Output

Source-checked

Shorted 24R Output

View on the FireClass FC501 page

FireClass FC501

Battery

Source-checked

The control panel's batteries charger is not working correctly

View on the FireClass FC501 page

FireClass FC501

DEFAULT DATA

Source-checked

The fire panel resets to default data

View on the FireClass FC501 page

FireClass FC501

Dirty level

Source-checked

Smoke detector only; the dirty threshold has been exceeded

View on the FireClass FC501 page

FireClass FC501

Display communication

Source-checked

Communication fault on display controller

View on the FireClass FC501 page

FireClass FC501

Earth

Source-checked

Leakage to earth

View on the FireClass FC501 page

FireClass FC501

FIRE SIGNAL FAULT

Source-checked

Both the CSG paths are down

View on the FireClass FC501 page

FireClass FC501

FIRE SIGNAL NOT ACK

Source-checked

The fire signal is not acknowledged from the central station. This fault is latched, per the source.

View on the FireClass FC501 page

FireClass FC501

Firmware main contr.

Source-checked

Checksum fault

View on the FireClass FC501 page

FireClass FC501

GATEWAY COMMUNICAT.

Source-checked

The CSG is installed but it is not communicating with the panel

View on the FireClass FC501 page

FireClass FC501

IP Communicator

Source-checked

Communication lost with IP controller

View on the FireClass FC501 page

FireClass FC501

IP receiver

Source-checked

Communication lost with IP receiver

View on the FireClass FC501 page

FireClass FC501

LOG Full

Source-checked

LOG fault

View on the FireClass FC501 page

FireClass FC501

Loop Communication

Source-checked

Communication loop fault controller

View on the FireClass FC501 page

FireClass FC501

Loop left short

Source-checked

Left side loop short

View on the FireClass FC501 page

FireClass FC501

Loop local short

Source-checked

Local short on loop controller

View on the FireClass FC501 page

FireClass FC501

Loop return open

Source-checked

Loop negative signal open

View on the FireClass FC501 page

FireClass FC501

Loop right short

Source-checked

Right side loop short

View on the FireClass FC501 page

FireClass FC501

Loop signal open

Source-checked

Loop positive signal open

View on the FireClass FC501 page

FireClass FC501

LOOP x NOISY

Source-checked

The devices on the loop x (= 1, 2 or 3) do not communicate properly with the panel; check the quality of wiring. This is a parameterised message covering any of the three loops, as printed in the source.

View on the FireClass FC501 page

FireClass FC501

Low battery

Source-checked

The control panel batteries are empty

View on the FireClass FC501 page

FireClass FC501

Mains fault

Source-checked

The control panel is not powered from the mains

View on the FireClass FC501 page

FireClass FC501

MFI x COMMUNIC.

Source-checked

The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…

View on the FireClass FC501 page

FireClass FC501

MFI x INy SHORT

Source-checked

The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4; y from 1 to 5); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond…

View on the FireClass FC501 page

FireClass FC501

MFI x SERIAL CHANN.

Source-checked

The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…

View on the FireClass FC501 page

FireClass FC501

No answer

Source-checked

Loop device does not answer

View on the FireClass FC501 page

FireClass FC501

Not programmed dev

Source-checked

Loop device without address

View on the FireClass FC501 page

FireClass FC501

Open circuit

Source-checked

Open circuit on input module

View on the FireClass FC501 page

FireClass FC501

Power supply

Source-checked

Main fault

View on the FireClass FC501 page

Browse by manufacturer

49 panels

Got the panel in front of you? Look the fault up.

Search fault records by panel, each showing its review status and the source document where one is cited, and ask the assistant when a message is not listed. A free account needs no card and includes 5 assistant questions and 20 fault searches a day.