Hyfire HY5000 Series
Fire Routing Fault
Indicates that there is a fault condition in the Fire Brigade signalling equipment.
View on the Hyfire HY5000 Series pageAdvanced MxPro 5
Fire Routing Fault
Yellow LED indicator. Indicates that there is a fault condition in the Fire Brigade signalling equipment. From the official Advanced MxPro5 User Manual (LED Status Indicators table, section 2.2). This is the User…
View on the Advanced MxPro 5 pageGlobal Fire Equipment Orion (2/4/8 Zone)
Zone/input fault
Individual zone and monitored input indicators are provided for both fire/alarm and fault conditions. A flashing zone/input Fault LED together with the general FAULT LED indicates a fault in that zone. The same…
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
AUX. SUPPLY FAULT
This indicates the auxiliary supply has a fault.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
BATTERY FAULT
This indicates there is a low voltage level on the batteries, or the battery charger circuit has failed.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
EARTH FAULT
When this indicator is on, there is leakage current flowing between the earth connection/wiring and any other wire connected to the panel.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
FAULT
This LED indicates any fault condition present on the panel. If there is a communication fault between the ORION and an ORION MINI-REP, a Sounder/Relay module or a GFE-ADLI V2 module, this LED flashes once per second.…
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
RM FAULT
If there is an RM output circuit fault, the general FAULT LED is lit and the DISABLE SELECTED ZONES LED in the Disablements section flashes.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
SOUNDER FAULT
If there is a conventional sounder output circuit fault, the general FAULT LED is lit and the DISABLE SOUNDERS LED in the Disablements section flashes.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
SUPPLY FAULT
This LED is on whenever the main supply has been removed or has dropped below 20 volts.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment Orion (2/4/8 Zone)
SYSTEM FAULT
This LED is lit whenever there is a processor failure or corruption of the panel firmware.
View on the Global Fire Equipment Orion (2/4/8 Zone) pageGlobal Fire Equipment G-One
Battery Fault
Displayed when the battery connection is broken (the manual's own test procedure is to temporarily remove the link wire between the batteries). After a short delay the SUPPLY FAULT LED comes on, the panel buzzer sounds,…
View on the Global Fire Equipment G-One pageGlobal Fire Equipment G-One
DEVICE NEEDS SERVICE
Reported via the normal fault mechanism (and logged) when programming function 6-3-5 "Check for Devices Needing Service" finds a ZEOS-protocol device close to its drift-compensation limit. No further cause or remedy…
View on the Global Fire Equipment G-One pageGlobal Fire Equipment G-One
NO COMMS TO PANEL
Shown on a remote Chameleon Display (not the main panel itself) when, after initialization, serial communication between the panel and the display has not been established. The FAULT LED on the display is also lit. The…
View on the Global Fire Equipment G-One pageGlobal Fire Equipment G-One
PANEL CONFIGURATION MISMATCH
The G-One has detected that Chameleon network panels do not hold the same system configuration or operating mode.
View on the Global Fire Equipment G-One pageGlobal Fire Equipment G-One
Primary Supply Fault
Displayed when the mains AC supply to the panel fails or is switched off. After a short delay the amber SUPPLY FAULT LED comes on and the fault buzzer sounds. Cleared when mains is restored and SYSTEM RESET is pressed.
View on the Global Fire Equipment G-One pageGlobal Fire Equipment OCTO+
Battery Fault
Displayed when the battery connection is broken (the manual's own test procedure is to temporarily remove the wire linking the batteries). After a short delay the SUPPLY FAULT LED comes on, the panel buzzer sounds, and…
View on the Global Fire Equipment OCTO+ pageGlobal Fire Equipment OCTO+
NO COMMS TO PANEL
Shown on a remote Chameleon Display (not the main panel itself) when, after initialization, serial communication between the panel and the display has not been established. The FAULT LED on the display is also lit.…
View on the Global Fire Equipment OCTO+ pageGlobal Fire Equipment OCTO+
No nodes detected
Given in the source only as an illustrative example ("Example: 'No nodes detected'") of the network status/error text shown by programming function 8-5-3 "Installation Status", which reports the status of the network.…
View on the Global Fire Equipment OCTO+ pageGlobal Fire Equipment OCTO+
PANEL CONFIGURATION MISMATCH
The OCTO+ has detected that Chameleon network panels do not hold the same system configuration or operating mode.
View on the Global Fire Equipment OCTO+ pageGlobal Fire Equipment OCTO+
Primary Supply Fault
Displayed when the mains AC supply to the panel fails or is switched off. After a short delay the amber SUPPLY FAULT LED comes on and the fault buzzer sounds. Cleared when mains is restored and SYSTEM RESET is pressed.
View on the Global Fire Equipment OCTO+ pageSiemens Fire Safety Cerberus PRO FC726
Remote alarm Fault / Off (LED 8)
Transmission equipment has a 'Fault'. Action: Check remote transmission.
View on the Siemens Fire Safety Cerberus PRO FC726 pageC-TEC MFP Range (4-28 Zone) Conventional Fire Alarm Panel
Processor Fault
Accompanied by a permanent fault beeper tone. Indicates the panel's microprocessor failed to execute its programme correctly and a safety circuit restarted it — can be caused by a sudden interruption of all power,…
View on the C-TEC MFP Range (4-28 Zone) Conventional Fire Alarm Panel page