Panel fault records

Fault records by panel

Fault records for a small, deliberately staged set of panels. Each record is labelled with its review status and, where one is cited, the source document and page it comes from. More panels are added as more records go through source review.

Searches 148 records across 6 panels.

30+ matches for “MxPro 4”

Advanced MxPro 5

Device Missing

Not yet verified

The panel display shows the affected zone and device text with "DEVICE MISSING" alongside the device type (e.g. "(MULTI.SENSOR)"), from a worked example in the official Advanced MxPro5 User Manual (section 3.3, Fault…

View on the Advanced MxPro 5 page

Advanced MxPro 5

Fire Routing Fault

Not yet verified

Yellow LED indicator. Indicates that there is a fault condition in the Fire Brigade signalling equipment. From the official Advanced MxPro5 User Manual (LED Status Indicators table, section 2.2). This is the User…

View on the Advanced MxPro 5 page

Advanced MxPro 5

Sounder Fault

Not yet verified

Yellow LED indicator. Indicates the presence of a fault in one or more sounder wiring circuits. From the official Advanced MxPro5 User Manual (LED Status Indicators table, section 2.2). This is the User Manual, not the…

View on the Advanced MxPro 5 page

Advanced MxPro 5

System Fault

Not yet verified

Yellow LED indicator. Indicates the presence of a system fault. From the official Advanced MxPro5 User Manual (LED Status Indicators table, section 2.2). This is the User Manual, not the fuller Installation and…

View on the Advanced MxPro 5 page

Advanced MxPro 5

AUX LOAD TOO HIGH

Not yet verified

The panel's auxiliary 24V output current draw is above its normal operating range (0-500mA) — an overload on equipment powered from the AUX terminals. From the official Advanced MxPro5 User Manual's Local Hardware…

View on the Advanced MxPro 5 page

Advanced MxPro 5

BATTERY LOW

Not yet verified

The standby battery voltage has dropped below the panel's normal operating band (nominally 27.6V). From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists…

View on the Advanced MxPro 5 page

Advanced MxPro 5

BATTERY TOO HIGH

Not yet verified

The standby battery voltage is above the panel's normal operating band. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the…

View on the Advanced MxPro 5 page

Advanced MxPro 5

CHARGER TOO HIGH

Not yet verified

The battery charger's output voltage reading is above the normal operating band. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of…

View on the Advanced MxPro 5 page

Advanced MxPro 5

CHARGER TOO LOW

Not yet verified

The battery charger's output voltage reading is below the normal operating band (nominally 28.0V). From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists…

View on the Advanced MxPro 5 page

Advanced MxPro 5

DEVICE CONTAMINATION

Not yet verified

Raised against an analogue loop device once its measured compensation-drift value exceeds a preset limit — typically dust or contamination affecting a detector's chamber over time. Preceded by a non-fault "Warning"…

View on the Advanced MxPro 5 page

Advanced MxPro 5

Earth fault

Not yet verified

The panel's internal earth-monitoring circuit reads outside its normal band, typically indicating cable insulation breakdown or earth leakage. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic…

View on the Advanced MxPro 5 page

Advanced MxPro 5

LOOP LOAD TOO HIGH

Not yet verified

The loop current reading is above the normal operating range — an overload condition on the detection loop. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23),…

View on the Advanced MxPro 5 page

Advanced MxPro 5

LOOP OPEN CIRCUIT

Not yet verified

The loop current reading indicates an open-circuit state — a break, loose terminal or removed device on the detection loop. All devices beyond the break will be reported as missing; short circuit isolators (SCIs), if…

View on the Advanced MxPro 5 page

Advanced MxPro 5

LOOP SHORT CIRCUIT

Not yet verified

The loop current reading indicates a short-circuit state on the detection loop. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the…

View on the Advanced MxPro 5 page

Advanced MxPro 5

SERVICE DUE

Not yet verified

The panel raises this fault once the programmed "next service due" date is reached, alerting the site operator that a maintenance visit is overdue. It clears automatically once a new service date is entered. From the…

View on the Advanced MxPro 5 page

Advanced MxPro 5

SOUNDER CIRCUIT OPEN CIRCUIT

Not yet verified

A supervised sounder output circuit (Sounder A/B, and C/D on the 5400) reads open circuit. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as…

View on the Advanced MxPro 5 page

Advanced MxPro 5

SOUNDER CIRCUIT SHORT CIRCUIT

Not yet verified

A supervised sounder output circuit reads short circuit. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the possible circuit…

View on the Advanced MxPro 5 page

Advanced MxPro 5

SOUNDER LOAD TOO HIGH

Not yet verified

A sounder circuit's load current is above the normal operating range. From the official Advanced MxPro5 User Manual's Local Hardware diagnostic table (section 3.9.7.2, pp.22–23), which lists this as one of the possible…

View on the Advanced MxPro 5 page

Advanced MxPro 4

Aux Supply Too High

Not yet verified

From the panel's own "View - Panel" diagnostic table: Aux Supply is monitored 0mA-500mA; the panel reports Too High when the current exceeds the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Battery Too High

Not yet verified

From the panel's own "View - Panel" diagnostic table: Battery is monitored 0V-30V, normal >25.0V; the panel reports Too High when the reading exceeds the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Battery Too Low

Not yet verified

From the panel's own "View - Panel" diagnostic table: Battery is monitored 0V-30V, normal >25.0V under full load. Per the manual's own note, the voltage shown is measured under full load conditions; if it falls below…

View on the Advanced MxPro 4 page

Advanced MxPro 4

Charger Too High

Not yet verified

From the panel's own "View - Panel" diagnostic table: Charger is monitored 0V-30V, normal 27.6V; the panel reports Too High when the reading exceeds the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Charger Too Low

Not yet verified

From the panel's own "View - Panel" diagnostic table: Charger is monitored 0V-30V, normal 27.6V; the panel reports Too Low when the reading falls below the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

DEVICE MISSING

Not yet verified

Shown against the specific loop address, zone and location text on the display, e.g. "1 004.0 DEVICE MISSING" under the zone's fault list. Indicates the panel is no longer receiving a response from that addressed device.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Earth Monitor Too High

Not yet verified

From the panel's own "View - Panel" diagnostic table: Earth Monitor is monitored 0V-30V, normal 1.3V; the panel reports Too High when the reading exceeds the expected range. Whether Earth Fault is shown on the display…

View on the Advanced MxPro 4 page

Advanced MxPro 4

Earth Monitor Too Low

Not yet verified

From the panel's own "View - Panel" diagnostic table: Earth Monitor is monitored 0V-30V, normal 1.3V; the panel reports Too Low when the reading falls below the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Fire Routing Fault

Not yet verified

Applies only when the Routing Interface is set to Monitored (Section 3.3.15.8). Function LED3 (Yellow) indicates a fault in the transmission path of the fire routing connection, and also illuminates if there is a fault…

View on the Advanced MxPro 4 page

Advanced MxPro 4

Loop Load Too High

Not yet verified

From the panel's own "View - Panel" diagnostic table: each loop's load is monitored 0mA-500mA; the panel reports Too High when the current exceeds the expected range.

View on the Advanced MxPro 4 page

Advanced MxPro 4

Loop Open Circuit

Not yet verified

From the panel's own "View - Panel" diagnostic table: each loop's load is monitored 0mA-500mA; the panel reports Open Circuit when the reading falls outside that range in the open direction. Loop Load, V.Out and V.In…

View on the Advanced MxPro 4 page

Advanced MxPro 4

Loop Short Circuit

Not yet verified

From the panel's own "View - Panel" diagnostic table: each loop's load is monitored 0mA-500mA; the panel reports Short Circuit when the reading falls outside that range in the short direction.

View on the Advanced MxPro 4 page

Panels