Zeta Simpo

Fault Output Open

Source-checked

Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fault output. The manual gives no cause or action for this message.

View on the Zeta Simpo page

Zeta Simpo

Chamber Fault

Source-checked

Fault in the detector.

View on the Zeta Simpo page

Zeta Simpo

Fault Output Short

Source-checked

Short circuit detected at Fault output.

View on the Zeta Simpo page

Zeta Simpo

Fault Protection Panel Input Open

Source-checked

Circuit broken at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

Fault Protection Panel Input Short

Source-checked

Short circuit detected at input 'Protection Panel Fault'.

View on the Zeta Simpo page

Zeta Simpo

GENERAL FAULT

Source-checked

Lights on permanently in case of a fault event in the system.

View on the Zeta Simpo page

Zeta Simpo

Loop Device Input Fault

Source-checked

Fault in loop device input.

View on the Zeta Simpo page

Zeta Simpo

Loop Device Output Fault

Source-checked

Fault in loop device output.

View on the Zeta Simpo page

Zeta Simpo

Panel Fault

Source-checked

Fault in the connection with another panel, when two or more panels are connected in a network.

View on the Zeta Simpo page

Zeta Simpo

SYSTEM FAULT

Source-checked

CPU FAULT. Lights on permanently in case of main microprocessor fault.

View on the Zeta Simpo page

Zeta Simpo

Fault Power AUX

Source-checked

As given in the source's own event table: "Short circuit (the mains power supply is lost)" — the source's wording for this entry is terse and possibly abbreviated; quoted as written rather than expanded.

View on the Zeta Simpo page

Zeta Simpo

Charger Fault

Source-checked

The charging unit is failed.

View on the Zeta Simpo page

Zeta Simpo

Earth Fault

Source-checked

Resistive connection between some signals and earth, below 10kΩ.

View on the Zeta Simpo page

Zeta Simpo

Log Fault

Source-checked

The log file event is lost or damaged.

View on the Zeta Simpo page

Zeta Simpo

Loop Device Fault

Source-checked

The device does not respond (lost or damaged).

View on the Zeta Simpo page

Zeta Simpo

Periphery Device Fault

Source-checked

The device is not responding (the device is lost or failed).

View on the Zeta Simpo page

Zeta Simpo

Protection Panel Fault

Source-checked

The extinguishing panel failure.

View on the Zeta Simpo page