Zeta Simpo
Fault Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fault output. The manual gives no cause or action for this message.
View on the Zeta Simpo pageZeta Simpo
Chamber Fault
Fault in the detector.
View on the Zeta Simpo pageZeta Simpo
Fault Output Short
Short circuit detected at Fault output.
View on the Zeta Simpo pageZeta Simpo
Fault Protection Panel Input Open
Circuit broken at input 'Protection Panel Fault'.
View on the Zeta Simpo pageZeta Simpo
Fault Protection Panel Input Short
Short circuit detected at input 'Protection Panel Fault'.
View on the Zeta Simpo pageZeta Simpo
GENERAL FAULT
Lights on permanently in case of a fault event in the system.
View on the Zeta Simpo pageZeta Simpo
Loop Device Input Fault
Fault in loop device input.
View on the Zeta Simpo pageZeta Simpo
Loop Device Output Fault
Fault in loop device output.
View on the Zeta Simpo pageZeta Simpo
Panel Fault
Fault in the connection with another panel, when two or more panels are connected in a network.
View on the Zeta Simpo pageZeta Simpo
SYSTEM FAULT
CPU FAULT. Lights on permanently in case of main microprocessor fault.
View on the Zeta Simpo pageZeta Simpo
Fault Power AUX
As given in the source's own event table: "Short circuit (the mains power supply is lost)" — the source's wording for this entry is terse and possibly abbreviated; quoted as written rather than expanded.
View on the Zeta Simpo pageZeta Simpo
Charger Fault
The charging unit is failed.
View on the Zeta Simpo pageZeta Simpo
Earth Fault
Resistive connection between some signals and earth, below 10kΩ.
View on the Zeta Simpo pageZeta Simpo
Log Fault
The log file event is lost or damaged.
View on the Zeta Simpo pageZeta Simpo
Loop Device Fault
The device does not respond (lost or damaged).
View on the Zeta Simpo pageZeta Simpo
Periphery Device Fault
The device is not responding (the device is lost or failed).
View on the Zeta Simpo pageZeta Simpo
Protection Panel Fault
The extinguishing panel failure.