Fault records by panel
Search fault records across 49 panels. Each record is labelled with its review status and, where one is cited, the source document and page it comes from.
Searches 608 records across 49 panels — 573 of them source-verified. Signed in, your dashboard fault search covers only the fully source-verified records, on any plan.
Want to test yourself? Try the free daily fault challenge.
30+ partial matches for “VESDA-E VES”
Nothing matched every word, so these match some of them. Check the record and panel before relying on it.
We do not hold published fault records for Xtralis, so these are not Xtralis records.
C-TEC XFP
Investigating a device with INTENSIVE DEVICE MONITOR
Per the manual, this function monitors one addressable point under intensive, repeated polls from the panel, and reports how many good and bad polls occur between the panel and the device, which can help pinpoint loop…
View on the C-TEC XFP pageZiton ZP2-FR
Battery charger: compensation
The source lists this as one of five additional battery charger fault messages that may display, beyond the four in Table 66, but gives no individual cause or remedy text for any of the five beyond the message name…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Battery charger: overvoltage
The source lists this as one of five additional battery charger fault messages that may display, beyond the four in Table 66, but gives no individual cause or remedy text for any of the five beyond the message name…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Battery charger: sensor HI
The source lists this as one of five additional battery charger fault messages that may display, beyond the four in Table 66, but gives no individual cause or remedy text for any of the five beyond the message name…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Battery charger: sensor LO
The source lists this as one of five additional battery charger fault messages that may display, beyond the four in Table 66, but gives no individual cause or remedy text for any of the five beyond the message name…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Battery charger: undervoltage
The source lists this as one of five additional battery charger fault messages that may display, beyond the four in Table 66, but gives no individual cause or remedy text for any of the five beyond the message name…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Fire protection fault
The yellow Fire Protection Fault/Disabled/Test LED indicates a fire protection fault, disablement, or test. A flashing LED indicates a fault; a steady LED indicates a disablement or a test. From the ZP2 Series…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Firenet panel offline
If a control panel previously configured to be in the fire network is not detected, a fault message indicating the offline status (with the Firenet ID) is reported. From the ZP2 Series Installation Manual, "Firenet…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Mains / mains fuse fault
The yellow Supply Fault LED indicates a power supply fault. A steady LED indicates a mains or mains fuse fault (a flashing LED indicates a battery fault). From the ZP2 Series Installation Manual, Table 3 "Common…
View on the Ziton ZP2-FR pageZiton ZP2-FR
Sounder fault
The yellow Sounder Fault/Disabled/Test LED indicates a sounder fault, disablement, or test. A flashing LED indicates a fault; a steady LED indicates a disablement or a test. From the ZP2 Series Installation Manual,…
View on the Ziton ZP2-FR pageFike Twinflex
SYSTEM FAULT LED (flashing, write enable)
Yellow SYSTEM FAULT indicator, flashing: the manual says this LED is also illuminated if the write protect / write enable switch is left on while the system is not in the engineer menu. In access levels 1 and 2 a system…
View on the Fike Twinflex pageZeta Simpo
EXT Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Extinguishing output. The manual gives no cause or action for this message.
View on the Zeta Simpo pageZeta Simpo
Fault Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fault output. The manual gives no cause or action for this message.
View on the Zeta Simpo pageZeta Simpo
Fire Output Open
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: Circuit broken at Fire output. The manual gives no cause or action for this message.
View on the Zeta Simpo pageZeta Simpo
New Loop Devices Found
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: New loop devices are found in system configuration. The manual gives no cause or action for this message.
View on the Zeta Simpo pageZeta Simpo
New Periphery Devices Found
Event message on the SIMPO addressable panel. The manual's Appendix A table describes it as: New periphery devices are found in the system configuration. The manual gives no cause or action for this message.
View on the Zeta Simpo pageNittan Evolution
DOUBLE ADDRESS FAULT
Two or more devices may have the same address setting. All devices with the same address will answer at the same time and the panel will not be able to understand the reply it receives. Search the detailed loop report…
View on the Nittan Evolution pageFireClass FC501
MFI x COMMUNIC.
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…
View on the FireClass FC501 pageFireClass FC501
MFI x INy SHORT
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4; y from 1 to 5); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond…
View on the FireClass FC501 pageFireClass FC501
MFI x SERIAL CHANN.
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…
View on the FireClass FC501 pageFireClass FC501
PRINTER x ABSENT
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…
View on the FireClass FC501 pageFireClass FC501
PRINTER x FAULT
The source names this fault message and gives only the applicable module/input numbering (x from 1 to 4); it states no cause, meaning, or remedy beyond that numbering. No cause is asserted here beyond what the source…
View on the FireClass FC501 pageSiemens Fire Safety Cerberus PRO FC726
Topology is invalid
Displayed after a C-NET detector line has been read in, if the topology of that line is invalid (source gives four invalid-topology diagrams: stub on stub or loop interrupted; stub on stub on loop; several stubs…
View on the Siemens Fire Safety Cerberus PRO FC726 pageProtec 6100
General fault handling
The manual says that when the 6100 detects a fault in any of the critical operating paths it shows it on the front panel display and the internal buzzer pulses slowly. The General Fault indicator is illuminated and is…
View on the Protec 6100 pageMorley-IAS DX (Dimension Series DX1e/DX2e/DX4e)
INPUT OPEN CIRCUIT
Panel fault text shown on the DX display. The manual's example shows it as an input open circuit on 'Monitored Input 1' registered at 12:15, as one of three panel-related faults. The manual gives it only as an example…
View on the Morley-IAS DX (Dimension Series DX1e/DX2e/DX4e) pageMorley-IAS DX (Dimension Series DX1e/DX2e/DX4e)
NO REPLY FROM DEVICE
Fault text shown on the DX display for a loop device. The manual's examples show it beside the zone, loop number, device address (for example L1 A010), device type and the time the device entered the fault condition.…
View on the Morley-IAS DX (Dimension Series DX1e/DX2e/DX4e) pageFike Safety Technology CIE-A-200
Device faults during initialisation
Per the manual, if the system detects a device fault or fire activation during initialisation, initialisation does not fail at that point. Beyond certain limits initialisation will fail and the various fault or fire…
View on the Fike Safety Technology CIE-A-200 pageFike Safety Technology CIE-A-200
Earth Fault
Per the manual, if the panel detects a short circuit or leakage current to earth/screen from one of its supply rails (0 V or +Ve) an Earth Fault is displayed. The normal voltage between 0 V and Earth SCRN is 1.7 V; the…
View on the Fike Safety Technology CIE-A-200 pageFike Safety Technology CIE-A-200
Loop not complete (loop +ve to -ve short circuit or +ve open circuit at initialisation)
Per the manual, if the system faces a loop +ve to -ve short circuit or a loop +ve open circuit during initialisation, initialisation fails at that point and a message of Loop not complete is displayed. Devices up to…
View on the Fike Safety Technology CIE-A-200 pageFike Safety Technology Quadnet
Smoke Sensor Failed - Signal High
Per the manual: make sure the correct device is being investigated by comparing its description with the device address and/or serial number; make sure the optical chamber is clean, and if not replace it with a new one…
View on the Fike Safety Technology Quadnet page