Fault records by panel
Search fault records across 49 panels. Each record is labelled with its review status and, where one is cited, the source document and page it comes from.
Searches 608 records across 49 panels — 573 of them source-verified. Signed in, your dashboard fault search covers only the fully source-verified records, on any plan.
Want to test yourself? Try the free daily fault challenge.
30+ partial matches for “Zeta Alarm Systems manuals”
Nothing matched every word, so these match some of them. Check the record and panel before relying on it.
Zeta Simpo
Alarm Confirm Input Open
Circuit broken at input 'Alarm Confirmation'.
View on the Zeta Simpo pageZeta Simpo
Alarm Confirm Input Short
Short circuit detected at input 'Alarm Confirmation'.
View on the Zeta Simpo pageZeta Simpo
Protection Alarm Confirm Open
Circuit broken at input 'Protection Alarm Confirmation'.
View on the Zeta Simpo pageZeta Simpo
Protection Alarm Confirm Short
Short circuit detected at input 'Protection Alarm Confirmation'.
View on the Zeta Simpo pageZeta Premier Elite (4 to 8 zone)
Sounder circuit fault: short circuit (Gen S/C LED lit)
Per the manual, a sounder short circuit fault lights the Gen S/C LED. Check the correct end of line (10K resistor) has been fitted to both circuits; check that all sounders and bells are polarised and fitted the correct…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Earth fault
Per the manual, an earth fault indicates that something is shorting to earth, usually through the cable screen. Disconnect the earth screens one at a time to determine the problem line. Connecting other equipment, for…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Faults are non-latching (system fault excepted)
The manual says most faults need checking by an engineer, but the system can be checked for a removed detector by the responsible person. All faults in the Premier Elite are non-latching: they cannot be reset with the…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Sounder circuit fault: open circuit
Per the manual, for a sounder open circuit fault: check that the correct end-of-line resistor (10K) has been fitted to both circuits; check sounder fuses FS4 and FS5 are intact; check there are no breaks in the cable…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Supply fault
Per the manual, a power supply fault indicates loss of mains power or loss of battery power. For loss of mains: check that 230 V AC is present at the mains terminal block, check the mains fuse, check that there is 30 to…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
System fault
Per the manual, a system fault is an abnormal microprocessor running condition due to various unexpected phenomena, and the panel attempts to correct itself. The System Fault LED, General Fault LED, General Fault relay…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Zone fault: open circuit
Per the manual, an open circuit zone fault: check that the correct end-of-line diode (1N4002) has been fitted; check there are no breaks in the cable and all screw connections are secure; check no detectors have been…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier Elite (4 to 8 zone)
Zone fault: short circuit (Gen S/C LED lit)
Per the manual, a short circuit zone fault lights the Gen S/C LED. Check that the correct end of line (1N4002 diode) has been fitted and not backwards (stripe to +ve); check that no equipment other than detectors or…
View on the Zeta Premier Elite (4 to 8 zone) pageZeta Premier
5/8V
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: 5 V supply low.
View on the Zeta Premier pageZeta Premier
BATT
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Battery fault.
View on the Zeta Premier pageZeta Premier
CHARGE
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Charger fault.
View on the Zeta Premier pageZeta Premier
D.FLT
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Data Fault: the analogue value reported by the device is not valid.
View on the Zeta Premier pageZeta Premier
DADDR
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Double Address: two or more devices exist with the same address.
View on the Zeta Premier pageZeta Premier
EARTH
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Earth fault, printed in the manual as “Earth fault (disabled)”; the diagram beside it shows the earth fault monitoring…
View on the Zeta Premier pageZeta Premier
FUSE FAILED
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Auxiliary power supply fuse failed.
View on the Zeta Premier pageZeta Premier
L/BATT
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Low battery voltage (below 19 V).
View on the Zeta Premier pageZeta Premier
LINE FAULT
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Open circuit fault detected in the loop cable. This may be due to an operation of short circuit isolators.
View on the Zeta Premier pageZeta Premier
MAIN
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Input from the SMPS out of tolerance.
View on the Zeta Premier pageZeta Premier
PROC
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: P.S.E. processor fault.
View on the Zeta Premier pageZeta Premier
PSU OK
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Power supply healthy; the indicator switches off for 1 second every 30 seconds during the battery discharge test.
View on the Zeta Premier pageZeta Premier
R.FLT
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Remote Fault at the address indicated.
View on the Zeta Premier pageZeta Premier
RMVD
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Removed: the loop device is not responding.
View on the Zeta Premier pageZeta Premier
System fault (complete system failure)
Per the manual, in the event of a complete system failure a system fault is indicated: the SYSTEM FAULT and GENERAL FAULT LEDs illuminate and all other LEDs are extinguished; the internal buzzer sounds continuously; the…
View on the Zeta Premier pageZeta Premier
The Fault Condition (general response)
Per the manual, a fault is indicated if any part of the system enters an abnormal condition. The COMMON FAULT LED pulses (and the ALARM FAULT/DISABLEMENT LED also pulses if the fault is with an alarm circuit), the…
View on the Zeta Premier pageZeta Premier
THERM
Power supply status indicator on the Zeta Premier AL power supply board. The manual lists it as: Thermistor fault.
View on the Zeta Premier pageZeta Premier
W.TYPE / WTYPE
LCD event text on the Zeta Premier AL. The manual's Appendix D describes it as: Wrong Type: the device at this address is different from that configured for the address.
View on the Zeta Premier page